Step 2 — Connect the System
Connecting by RS-232 / RS-422
• Connect the Imager (1) to the IB-3PC interface (2).
• Connect the comm. cable (
4
) to the host (
5
) and to the host connector on
the IB-3PC (
2
).
• Connect power supply (3) to the IB-3PC (2).
• Apply power to the Imager.
Connecting by USB
• Plug the MS-4 Imager’s USB cable into a host USB port.
• Apply power to the Imager.
Hardware Configuration
Caution:
Be sure that all cables are connected
BEFORE
applying power
to the system. Always power down
BEFORE
disconnecting any cables.
Step 1 — Check Hardware
Item Description Part Number
1
MS-4 Imager FIS-0004-XXXXG
2
IB-3PC Interface Box FIS-0001-0030
3
Power Supply
97-100002-04 (110V)
97-100002-05 (220V)
4
Comm. Cable 61-000010-01
Quick Start Guide
MS-4 Imager
P/N 83-200004-04 Rev A
Step 3 — Position Imager
•
Position the Imager at a distance from the symbol that matches the factory
pre-set focal distance. For example, if your Imager is pre-set at 4”, position
the parting line 4” from the symbol.
• Tip the Imager relative to the symbol to avoid the glare of direct (specular)
reflection. The case parting line should be perpendicular to the plane of the
symbol by either pitching the symbol or the Imager as shown.
• Position the Imager in a place with as little ambient light as possible.
• Symbols can be rotated (tilted) at any angle; however, for best results
symbols should be aligned with the FOV (field of view).
• In the case of linear symbols, aligning the bars in the direction of their
movement (“ladder” orientation) will minimize the chances of blurring,
and will produce better reads.
• Avoid excessive skew or pitch. Maximum skew is
±30°
; maximum pitch is
±30°
.
Note: For instant setup and validation, the MS-4 can be hand-held or
placed on its side. For accuracy, however, Microscan’s mounting arm
adapter kits (P/N 98-000048-01 or -02) are recommended.
Imager / Symbol Positioning
±30°
Step 4 — Install ESP
ESP Software can be found on the Microscan Tools Drive that is packaged
with the MS-4 Imager.
1. Follow the prompts to install ESP from the Tools Drive.
2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at
www.microscan.com.
Minimum System Requirements
• 233 MHz Pentium PC
• Windows 8, 7, Vista, or XP operating system
(32-bit or 64-bit)
• Internet Explorer 6.0 or higher
• 128 MB RAM or greater
• 160 MB free disk space
• 800 x 600 256 color display (1024 x 768 32-bit color recommended)
Refer to the MS-4 Imager User Manual for detailed information about using
ESP to configure the MS-4.
Step 5 — Select Model
When you start ESP, this menu will appear:
• Select the MS-4 from the menu and click OK. If you do not want to make
this selection every time you start ESP, uncheck “Show This Window at
Startup”.
• Click Yes when this dialog appears:
Note: If you need to select
another reader model later,
click the Switch Model button
near the top of the screen.
Comentários a estes Manuais