Microscan MS-4Xi Manual do Utilizador Página 109

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 360
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 108
MS-4Xi Imager User Manual
5-27
Read Cycle
Setting Up the Imager for EZ Trax
If you are using EZ Trax software, it is important to set up the MS-4Xi correctly before
beginning.
Click the Read Cycle tab to display the Read Cycle tree control.
Set Trigger Mode, <K200>, to External Edge.
Set Capture Mode, <K241>, to Rapid Capture.
Once these Read Cycle parameters are set, you will be ready to connect to EZ Trax. For a
description of how to configure
EZ Trax
using serial commands or
ESP
, see
Configuring EZ
Trax Output
in
I/O Parameters
.
For more detailed information about using EZ Trax, refer to the Help menu in EZ Trax
software, or the EZ Trax Quick Start Guide, available on the Microscan Tools Drive.
Vista de página 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 359 360

Comentários a estes Manuais

Sem comentários