Quadrus EZ Reader User’s Manual 5-25
I/O Parameters
Video Output
Video Output Mode
Disabled
When selected the video output is disabled.
Triggered
Usage:
Useful for remote visual confirmation and review of images.
Note: Only available in the Quadrus EZ video option.
Definition:
Configures the operation of
video output of RS170 standard
video monitors. Video source
is configured via the Active
Camera command.
The video output can be confined
to a single event such as a
good read or can be fed as
continuous live video.
Serial Cmd: <K760,video output mode,trigger image mode,image frame>
Default: Trigger event
Options: 0 = Disabled 1 = Triggered 2 = Live (real time)
Usage: Ideal for dynamic applications.
Definition:
Outputs specific capture to the video output port as per the setting in
Triggered Mode.