MS-2 CCD Reader User’s Manual 1-7
Quick Start
Step 6 — Position the Reader
Set up a symbol at the distance you will be using in your application. Refer to the Read
Ranges for your MS-2 model (High Density or Low Density) to determine the optimal
distance.
Note: If you are using an Interleaved 2 of 5 symbol, verify that the number or characters
being scanned matches the symbol length enabled for I 2/5 (default is 10 and 6).
Avoid bright light or infrared light from other sources, including other readers.
Pitch the reader or symbol at a minimum of ±15° to avoid specular reflection (the return
of direct, non-diffused light).
Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°.
Note: Code 39 is the default symbology enabled. If you are uncertain of your symbology,
perform the following steps:
1. Enable all symbologies using ESP.
2. Enable Symbology Identifier at the bottom of ESP’s Symbologies tree control.
3. Decode the symbol and compare the symbology identifier character to the list on page
5-20 to determine your symbology.
4. Disable all other symbologies.
Pitch
axis
Bar code
label
Tilt
axis
Skew
axis
Scan line
Scanner
Reader and Symbol Orientation