Transition Counter
6-10 MS-820 Industrial Bar Code Scanner User’s Manual
6–Scanner Setup
Transition Counter
Used for both AGC and label detection routines (see Chapter 8, “Outputs”).
Transition Counter Status
Transition Counter Threshold
Definition: During the read cycle, the scanner counts the number of bar and space
transitions defined in the Transition Counter. If the count matches or
exceeds the threshold, the scanner will perform AGC routines. The
results of this test are also made known in output messages.See “Bar
Code Output,” on page 8-8 and “Bar Code Output,” on page 8-8.
Serial Cmd: <KH transition counter status,transition counter threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Determines the number of bar/space transitions that must be read
before a label is considered present and AGC can be resolved.
Usage: Can be useful in certain application where extraneous objects in the
field of view might require a higher threshold.
Serial Cmd: <KH transition counter status,transition counter threshold>
Default: 14
Options: 1 to 255