End of Read Cycle
4-12 MS-820 Industrial Bar Code Scanner User’s Manual
4–Read Cycle/Trig-
Timeout
Definition: Timeout ends the read cycle, causing the scanner to stop reading
labels and send the label data or noread message when the time set in
Timeout elapses (times out), if When to Output is set to End of
Read Cycle.
If in Continuous Read 1 Output, a timeout initiates a new read cycle
and allows the same label to be read again.
With either External Edge, Serial Data, or Serial Data & Edge
enabled, a timeout ends the read cycle and label data or a noread mes-
sage is sent to the host.
With External Level enabled, the read cycle does not end until the fall-
ing edge trigger or a timeout occurs. The next read cycle does not begin
until the next rising edge trigger.
Usage: Typically used with Serial or Edge and Continuous One.
It is effective in highly controlled applications when the maximum
length of time between objects can be predicted. It assures that a read
cycle ends before the next bar-coded object appears, giving the system
extra time to decode and transmit the data to the host.