HS-21/HS-41X Handheld Reader User’s Manual A-41
Appendices
C4 Default (Continuous) Event FF (#255)
The default value of FF (idle event) dis-
ables “continuous scanning”. Use one
of the read events to enable “continu-
ous scanning.” See setting 39 for the
list of events.
When no button is pressed but the
Reader is still in active mode (i.e., not
power-saving idle or sleep modes), this
event will be posted.
Also see register: 39
C7 Decoder Wide field (FOI1) Width 280 (#640)
Valid Range: 1 to 280 (#640) pixels
Decoder uses only the specified pixel
height in the Wide field (FOI1).
Also see registers: 9A, 9B, C8
C8 Decoder Wide field (FOI1) Height 3C0 (#960)
Valid Range: 1 to 3C0 (#960) pixels
Decoder uses only the specified pixel
height in the Wide field (FOI1).
Also see registers: 9A, 9B, C7
C9 Interleaved 2 Of 5 Lengths 0
FFFFFFFC: 2 and 4 digit disabled
FFFFFFFD: 2 digit enabled
FFFFFFFE: 4 digit enabled
Also see registers: 6E, 71
CD Codablock A Symbology 0
0: Disabled
1: Enabled
CE Codablock F Symbology 0
0: Disabled
1: Enabled
CF Macro PDF417 Symbology 0
0: Disabled
1: Enabled
Also see registers: 29, 2A
D8
Composite Codes Require Both Ele-
ments
1
0: Accept any composite element
1: Only accept composite codes if both
elements could be decoded.
Also see register 4A
EB
Maximum Reader To Host Packet Data
Size
4000
(#16384)
Valid Range: 1 to 4000 (#16384)
EC
Host Acknowledgement Time Limit
Multiplier (ms)
F (#15)
Valid Range: 0 to 7FFFFFFF Millisec-
onds
When Expect Acknowledgement From
Host (register 42) is nonzero, the
Reader will wait up to Host Acknowl-
edgement Time Limit (register 37) +
dataSize * Host Acknowledgement
Time Limit Multiplier (register EC) milli-
seconds to receive an acknowledge-
ment from the Host.
Comentários a estes Manuais