Chapter 9 Diagnostics
MS-9 Scanner User’s Manual 9-9
Present Operating Temperature (deg. C)
(This command is READ ONLY.)
Note: When viewing the Present Operating Temperature, allow at least 20 minutes
after startup for the scanner’s inside and outside temperatures to stabilize.
Usage: Used for setting Over Temperature Threshold and Under Tempera-
ture Threshold.
Definition: Indicates temperature of the environment immediately outside of the
scanner.
A thermal sensor on the main PCB measures the internal temperature of
the scanner. From this, a case-differential constant is subtracted to yield
an estimated external temperature.
Serial Cmd: Send: <K408?>
Returns <K408degrees Celsius>.