9-2 MS-4 Imager User’s Manual
Matchcode by ESP
Matchcode by ESP
Matchcode Serial Commands
Matchcode Type
<
K223,
matchcode type,sequential matching,match start
position,match length,wild card character,sequence on
No Read,sequence on mismatch>
Number of Master Symbols <K224,number of master symbols>
New Master Pin <K225,status>
Enter Master Symbol Data <K231,master symbol number,master symbol data>
Request Master Symbol Data
<
K231?,
>[for all]
or
<
K231?,
master symbol number>
Delete Master Symbol Data <K231,master symbol number,>
Match Replace <K735,status,match replacement string>
Mismatch Replace <K736,status,mismatch replacement string>