MS-4 Imager User’s Manual 9-9
Matchcode
Match Replace
Replacement String
Important: The ASCII characters <, >, and , can only be entered as hex pairs:
For <: <K735h,,3C>
For >: <K735h,,3E>
For
, : <K735h,,2C>
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
Usage: Provides a convenient shortcut for applications that need to output a
predefined text string whenever a symbol matches a master symbol.
Definition: Outputs a user-defined data string whenever a match occurs and
Matchcode is enabled.
Serial Cmd: <K735,status,replacement string>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: User-defined data string that, when enabled, replaces symbol data
whenever a match occurs.
Serial Cmd: <K735,status,replacement string>
Default: MATCH
Options: An ASCII string up to 64 characters.