Microscan MS-4X Manual do Utilizador Página 123

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 374
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 122
MS-4X Imager User Manual
5-27
Read Cycle
Setting Up the Imager for EZ Trax
If you are using EZ Trax software, it is important to set up the MS-4X correctly before
beginning.
Click the Read Cycle tab to display the Read Cycle tree control.
Set Trigger Mode, <K200>, to External Edge.
Set Capture Mode, <K241>, to Rapid Capture.
Once these Read Cycle parameters are set, you will be ready to connect to EZ Trax. For a
description of how to configure
EZ Trax
using serial commands or
ESP
, see
Configuring EZ
Trax Output
in
I/O Parameters
.
For more detailed information about using EZ Trax, refer to the Help menu in EZ Trax
software, or the EZ Trax Quick Start Guide, available on the Microscan Tools Drive.
Vista de página 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 373 374

Comentários a estes Manuais

Vikitpm 04 Jan 2024 | 14:20:38

urenrjrjkvnm

Evapsi 06 Jan 2024 | 23:41:38

Med