Microscan MS-4X Manual do Utilizador Página 64

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 374
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 63
3-20
MS-4X Imager Us
er Manual
Response Timeout
Response Timeout
Note: See USB HID Interface for protocol information relating to USB.
Usage: Only used when a response is required from the host. While in Multidrop, if
the imager does not receive an ACK or NAK from the host after sending
polled data, it will act on a fault. The reader can be set to wait indefinitely by
setting Response Timeout to zero.
Definition: The time that the imager will wait before timing out if ACK, NAK, and ETX
are enabled, and a host response is expected.
Serial Cmd: <K143,response timeout>
Default: 12 (in 1 ms increments)
Options: 0 to 255 (A zero (0) setting causes an indefinite wait.)
Vista de página 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 373 374

Comentários a estes Manuais

Vikitpm 04 Jan 2024 | 14:20:38

urenrjrjkvnm

Evapsi 06 Jan 2024 | 23:41:38

Med