Microscan MS-4X Manual do Utilizador Página 233

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 374
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 232
MS-4X Imager User Manual
9-5
Matchcode
Matchcode Type
Definition: Allows the user to choose the way that master symbols will be compared
with subsequently read symbols.
Note: First set Triggering Mode to External or Serial.
ESP:
Serial Cmd: <K223,matchcode type,sequential matching,match start position,
match length,wild card character,sequence on No Read,sequence on
mismatch>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
2 = Wild Card
3 = Sequential
Disabled: Has no effect on operations.
Enabled: Instructs the imager to compare symbols or portions of symbols with the
master symbol.
Wild Card: Allows the user to enter user-defined wild card characters in the master
symbol.
Sequential: Instructs the imager to sequence after each match (numeric only) and
compare symbols or portions of symbols for sequential numbers.
Note: If Matchcode Type is set to Sequential, the imager will behave
as if Number of Symbols were set to 1, regardless of the user-defined
configuration.
Vista de página 232
1 2 ... 228 229 230 231 232 233 234 235 236 237 238 ... 373 374

Comentários a estes Manuais

Vikitpm 04 Jan 2024 | 14:20:38

urenrjrjkvnm

Evapsi 06 Jan 2024 | 23:41:38

Med