Laser Framing
7-8 MS-3 Laser Scanner User’s Manual
7–Scanner Setup
Laser Off Position
Definition: Percentage of the full scan arc
that the scan beam moves
through before the laser turns
OFF.
Notes:
The combined values of Laser
On Position and Laser Off
Position cannot exceed 100 per-
cent, the total arc of one scan.
Laser Off Position must always
exceed the value of Laser On
Position for an actual laser scan
to take place.
Serial Cmd: <K700,laser on/off status,laser framing status,laser on position,laser
off position,laser power>
Default: 90
Options: 20 to 100
LASER
MS-3
Laser Off
Position
Figure 7-2 Laser Off Position