Microscan MS-4 Especificações Página 131

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 202
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 130
Chapter 8 Data Outputs
MS-3 Laser Scanner User’s Manual 8-9
8–Data Outputs
Bad Symbol Message
Bad Symbol Status
Bad Symbol Message
Definition: When enabled, a message is sent to the host when a symbol is detected
but not decoded. See “Transition Counter Threshold” on page 6-8.
The Bad Bar Code output is tied to the transition counter. If during a
read cycle no symbol is decoded and the required setting for the Tran-
sition Sample Threshold is met, a user defined message will be sent
to the host. See “Output Message Flow” on page 9-8.
Usage: Useful in verifying the presence of a bar code symbol that has not been
decoded.
Serial Cmd: <K715,bad symbol status,bad symbol message>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K715,bad symbol status,bad symbol message>
Default: BADCODE
Options: Up to seven ASCII characters (except NUL)
The Bad Bar Code output is tied to the transition counter. If during a
read cycle no symbol is decoded and the required setting for the Tran-
sition Sample Threshold is met, a user defined message will be sent
to the host.
Vista de página 130
1 2 ... 126 127 128 129 130 131 132 133 134 135 136 ... 201 202

Comentários a estes Manuais

Sem comentários