Vista de página 91
Code 93
5-24 MS-3 Laser Scanner User’s Manual
5–Symbology
Code 93
Code 93 Status
Fixed Code Length Status (Code 93)
Fixed Code Length (Code 93)
Definition: Code 93 is a variable length, continuous symbology employing four ele-
ment widths. Each Code 93 character has nine modules that may be
either black or white. Each character contains three bars and three
spaces.
Usage: Used occasionally in clinical industry.
Serial Cmd: <K475,status,fixed code length status,fixed code length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When enabled, the scanner will check the symbol length against the
code length field. When disabled, any length would be considered a
valid symbol.
Serial Cmd: <K475,status,fixed code length status,fixed code length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Specifies the exact number of characters that the scanner will recognize
(this does not include start and stop and check digit characters). The
scanner ignores any code not having the specified length.
Usage: Fixed Code Length helps prevent truncations and increases data
integrity by ensuring that only one symbol length will be accepted.
Serial Cmd: <K475,status,fixed code length status,fixed code length>
Default: 10
Options: 1 to 64