Microscan MS-4 Especificações Página 121

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 202
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 120
Chapter 7 Scanner Setup
MS-3 Laser Scanner User’s Manual 7-13
7–Scanner Setup
Bar Detection
Minimum Bar Transitions
Maximum Element
Definition: Allows the user to define the minimum number of bar transitions at
which a symbol will be detected.
Serial Cmd: <K502,(not used),minimum bar transitions,maximum element>
Default: 38 (bars)
Options: 5 to 255
Definition: Maximum Element represents the maximum bar element width, as
measured in micro seconds, that’s allowed before a video reset occurs
(default to white).
Usage: Caution: Do not change this parameter unless instructed by a Micros-
can representative.
Serial Cmd: <K502,(not used),minimum symbol transitions,maximum element>
Default: 1500 (45.75µS)
Options: 1 to 65535 (.035µS to 2294µS increments)
Vista de página 120
1 2 ... 116 117 118 119 120 121 122 123 124 125 126 ... 201 202

Comentários a estes Manuais

Sem comentários