6-4
EZ Match User Manual
Read Cycle Setup
Read Cycle Setup
Setting up Read Cycle and triggering parameters will involve a series of decisions based
on your particular application, as follows:
1. Select the number of symbols to be read in a single cycle. The EZ Match Imager ca
n
read
multiple symbols in a single image frame.
2. Decide on the trigger type to be used: if serial, choose a serial character; if extern
al,
choo
se either Level or Edge.
3. Designate how the read cycle should end (Timeout, New Trigger, Last Frame).
4. Select Capture Mode, Continuous Mode, or Rapid Capture Mode.
5. Select Number of Captures (if in Rapid Capture Mode).
6. Set the Time Before First Capture and Time Between Captures, if any.
Note: The imager’s camera captures images at a rate of about 16/second (based on a
full-size 1280 x 1024 monochrome image). The capture rate increases as frame sizes
decrease.