EZ Match User Manual
8-31
I/O Parameters
Configurable Output 1
Default Output Configuration
Output On
Note: If Output On is set to Mismatch/No Read or Match/Good Read, a transition
(switching) will not occur unless Matchcode Type is enabled and a master symbol is
loaded into memory.
Output # Output On: Output State Pulse Width Output Mode
1 8 = Tube/Cap Detection 0 = Negative 5 0 = Pulse
2 8 = Tube/Cap Detection 0 = Negative 5 0 = Pulse
3 0 = Mismatch or No Read 0 = Negative 5 0 = Pulse
Usage: This option provides discrete signalling to host software to control external
devices such as PLCs and relays. It is useful for routing, sorting, and to
prevent mis-packaging and mis-routing.
Definition: Sets the discrete output functions for specific user-selected conditions.
Allows the user to set the conditions under which an output (or outputs) will
be activated.
Serial Cmd:
<
K810,output on
,output state,pulse width,output mode>
Default: Tube/Cap Detection
Options: 0 = Mismatch or No Read
1 = Match or Good Read
2 = Mismatch
3 = No Read
4 = Trend Analysis
5 = Symbol Quality
6 = Diagnostic Warning
7 = In Read Cycle
8 = Tube/Cap Detection