EZ Match User Manual
6-5
Read Cycle
Multisymbol
Number of Symbols
Usage: Multisymbol is commonly used in shipping applications where a shipping
symbol contains individual symbols for part number, quantity, etc. This
feature allows on trigger to pick up all the symbols.
Definition: Multisymbol allows the user to define up to 100 symbols that can be read
in a single read cycle.
Conditions: The following conditions apply:
• Each symbol must be different to be read, unless in
Rapid Capture
Mode, configured for “triggered capture”.
• The maximum number of characters in a read cycle is 3,000 for
all
symbols.
•
All No Read messages are posted at the end of the data string, un
less
output
filtering is enabled.
• If more than one symbol is within the field of view at the same time,
symb
ol data may not be displayed in the order of appearance.
•
If
Matchcode Type
is set to
Sequential
or if
Trigger
is set to
Continuous
Re
ad 1 Output, the imager will behave as if Number of Symbols
were
set
to 1, regardless of the user-defined configuration.
Definition: This parameter has no function when a Multi-Operation read cycle is
active. Each operation index (1 through 3) requires one qualified output for
each active operation.
Example: If tube and cap detection are both enabled for operation index 1,
the required number of symbols for that index would be 2.
Important: The same symbol, tube, or cap can be processed and qualified
by two different operations in the same read cycle.
Serial Cmd: <K222,number of symbols, multisymbol separator>
Default: 1
Options: 1 to 100