Microscan EZ Match Imager Manual do Utilizador Página 294

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 431
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 293
11-24
EZ Match User Manual
Image Processing Timeout
Image Processing Timeout
Notes:
The timeout period does not include capture time.
If a timeout occurs during processing and no symbols in the field of view have been
decoded, the image will be recorded as a No Read. For this reason, a longer
timeout
sh
ould be tried to ensure that the symbol is decoded successfully.
Usage: Useful in higher speed applications where image processing time is long
enough that not all captures have an opportunity to be processed.
Definition: Specifies the maximum amount of time to process a captured image.
When the timeout expires, the image processing is aborted. This timeout
works in both Rapid Capture and Continuous Capture modes, as well
as with the IP Database.
Serial Cmd: <K245,image processing timeout>
Default: 5,000 ms (5 sec.)
Options: 1 to 65535 (in 1ms increments)
Vista de página 293
1 2 ... 289 290 291 292 293 294 295 296 297 298 299 ... 430 431

Comentários a estes Manuais

Sem comentários