EZ Match User Manual
8-45
I/O Parameters
Configurable Output 3
Note: Output 3 has the same parameters and default settings as Output 1 and Output 2.
Trend Analysis Output 3
Note: Output On
under
Output 3 Parameters
must be set to
Trend Analysis
(as shown
below) for this output to function.
ISO/IEC 16022 Symbol Quality Output 3
Note: Output On under Output 3 Parameters must be set to Symbol Quality
(as shown
below)
for this output to function.
Diagnostics Output 3
Note: Output On under Output 3 Parameters must be set to Diagnostic Warning
(as
shown below)
for this output to function.
Serial Cmd:
<
K812,
output on,output state,pulse width,output mode>
Serial Cmd:
<
K782,
trend analysis mode,trigger evaluation period,number to output
on,decodes/trigger threshold>
Serial Cmd:
<
K802,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non- uniformity
threshold,output on unused ECC,unused ECC threshold>
Serial Cmd: <K792,unused 1,service unit>