6-6
EZ Match User Manual
Multisymbol
Multisymbol Separator
Important: The ASCII characters <, >, and , can only be entered as hex
pairs:
For <: <K222h,,3C>
For >: <K222h,,3E>
For , : <K222h,,2C>
See ASCII Character Entry Modifier on page 4-33 for a more detailed
explanation of how to enter ASCII characters as hex values.
Note: If No Read messages are disabled and there are No Reads occurring,
separators will only be inserted between symbol data outputs.
Usage: Used to delimit or separate data fields with a user defined character.
Definition:
Any valid ASCII character, inserted between each symbol read when Multisymbol
is set to any number greater than 1.
Serial Cmd: <K222,number of symbols,multisymbol separator>
Default: , (comma)
Options: Any available ASCII character.