Microscan EZ Match Imager Manual do Utilizador Página 264

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 431
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 263
10-6
EZ Match User Manual
Matchcode Type
Wild Card Character
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K223h,,,,,3C>
For >: <K223h,,,,,3E>
For
, : <K223h,,,,,2C>
See ASCII Character Entry Modifier on page 4-33 for a detailed explanation of how to
enter ASCII characters as hex values.
Usage: Example: With Wild Card Character defined as the default asterisk,
defining CR*34 as the master symbol will result in matches for CR134
and CR234, but not CR2345. Entering the wild card at the end of the
master symbol, as in CR*, will result in matches for variable symbol
lengths such as CR1, CR23, CR358, etc.
Definition: Wild Card Character allows a user to define a wild card character as part
of the master symbol.
Serial Cmd: <K223,matchcode type,sequential matching,match start position,match
length,
wild card character
,sequence on No Read,sequence on mismatch>
Default: * (asterisk)
Options: Any ASCII character.
Vista de página 263
1 2 ... 259 260 261 262 263 264 265 266 267 268 269 ... 430 431

Comentários a estes Manuais

Sem comentários