5-58 QX Hawk Industrial Imager User Manual
Read Cycle
Capture Time
This command specifies the frame delays associated with the frames captured in a rapid
capture mode of operation.
Time Before 1st Capture
This value specifies the delay from the trigger to the first capture of any triggered read
cycle.
Time Between Captures 1-2
This value specifies the delay to wait before starting a frame capture for the next capture
in the rapid capture sequence.
Time Between Captures 2-3
This value specifies the delay to wait before starting a frame capture for the next capture
in the rapid capture sequence.
Time Between Captures 3-4
This value specifies the delay to wait before starting a frame capture for the next capture
in the rapid capture sequence.
Time Between Captures 4-5
This value specifies the delay to wait before starting a frame capture for the next capture
in the rapid capture sequence.
Time Between Captures 5-6
This value specifies the delay to wait before starting a frame capture for the next capture
in the rapid capture sequence.