A-100 QX Hawk Industrial Imager User Manual
Using EtherNet/IP
QX Hawk Big IN Assembly 0x65, 101 decimal (IN = QX Hawk -> PLC)
This contains more status information, and a longer bar code string, than the “Small IN
Assembly 0x64”. This gives the PLC visibility of the device’s discrete io, current operational
status, and read cycle counters.
Field # Data Type
Size (# of Data
Type Elements
Field Name
0U32 1
User-Defined Tag Echo
Echo from asm OUT 0xC6
1
U32
(32 bit flags)
1
Command Echo
Echo from asm OUT 0xC6
2
U32
(32 bit flags)
1
Output Control Echo
Echo from asm OUT 0xC6
3
U32
(32 bit flags)
1 External Input Status (Physical Pin State)
4
U32
(32 bit flags)
1 External Output Status (Physical Pin State)
5
U32
(32 bit flags)
1 Device Status
6U32 1
Read Cycle Sequence Counter:
When this value changes, it indicates the following
read cycle report fields have changed.
0 = Read cycle report has been “reset” to
“empty”.
Read cycle report data is only valid when
Sequence is not 0.
7 U32 1 Read cycle report: Trigger count <T>
8 U32 1 Read cycle report: Decode/Match count <V>
9 U32 1 Read cycle report: Mismatch count <X>
10 U32 1 Read cycle report: Noread count <N>
11 STRING 32 U32 + U8[128]
Read cycle report: Decoded Data
Up to 128, 8-bit chars
The first U32 is the length of the bar code data
in the U8[128] field.
Total=
176 U8,
or 44 U32