QX Hawk Industrial Imager User Manual 5-61
Parameters
Image Processing Settings
Number of Symbols in Field of View
Any Number of Symbols
No limit on number of symbols attempted to decode in an image frame.
One Symbol
Only one symbol will be decoded in an image frame, and this will be regardless of any
qualifying attributes associated with the read cycle.
Image Processing Timeout
Specifies the maximum amount of time allowed for image processing to spend on a captured
image. When the time-out expires, the image processing is aborted. This time-out works in
both rapid capture and continuous capture modes, as well as with the configuration database.
Notes:
The time-out period does not include capture time.
If a time-out occurs the image will be recorded as a No Read. This may cause some confusion
because the image may decode fine given enough time.