QX Hawk Industrial Imager User Manual 4-9
Setup
External Smart Light (QX Hawk C-Mount Only)
Disabled
When External Smart Light is set to Disabled, the external smart light control is disabled
and Output 3 is available for any other operation.
Always On
When External Smart Light is set to Always On, the external smart light is continuously on.
Always Off
When External Smart Light is set to Always Off, the external smart light is continuously off.
On Only When in Read Cycle
When External Smart Light is set to On Only When in Read Cycle, the external smart light
will be on when the imager is in an active read cycle.
Important Note: The external smart light's active state is controlled through the Output
State of Output 3, which is used as the external control line. To control the external light
using a Microscan standard 12-pin-to-5-pin external light control cable, set Output 3's
Output State to Normally Closed and Output Common to ground. Any other settings that
relate to Output 3, such as Output 3 Diagnostics will be ignored if this mode is enabled.
The external light will be continuously on until the system is fully re-booted.