QX Hawk Industrial Imager User Manual 4-25
Setup
Capture Index
Each index in the database (1 – 10) can be configured and tested individually.
Shutter Speed (CMOS)
Sets the camera’s shutter speed (60 – 40,000, default 2,500) for the selected index.
Shutter Speed (Standard QX Hawk CCD)
Sets the camera’s shutter speed (30 – 150,000, default 1,500) for the selected index.
Shutter Speed (QX Hawk C-Mount CCD)
Sets the camera’s shutter speed (30 – 150,000, default 2,500) for the selected index.
Gain (CMOS)
Sets the camera’s gain (0 – 33, default 20) for the selected index.
Gain (CCD)
Sets the camera’s gain (0 – 64, default 20) for the selected index.
Focal Distance (Standard QX Hawk Only)
Sets the camera’s focal distance (25 – 4,000, default 80) for the selected index.
Sub-Sampling (Standard QX Hawk Only)
Sets the sub-sampling rate (4:1 or 16:1, Disabled by default) for the selected index.
Important: Sub-Sampling has no effect when the “Image Dimension” mode is configured
as Region of Interest in the Database Mode command. This is because the camera Window
of Interest is determined by the software based on the database ROI setup and there is no
benefit to sub-sampling to increase speed, as the frame size would have to be increased
to account for the sub-sampling.