A-62 QX Hawk Industrial Imager User Manual
Serial Commands
Trigger Evaluation Period (Trend Analysis Output 1)
Number to Output On (Trend Analysis Output 1)
Decodes per Trigger Threshold (Trend Analysis Output 1)
Trend Analysis Output 2
Trend Analysis Output 3
Diagnostics Output 1
Service Unit (Diagnostics Output 1)
Diagnostics Output 2
Diagnostics Output 3
Serial Cmd:
<
K780,
trend analysis mode,
trigger evaluation period
,number to output on,
decodes per trigger threshold>
Default: 0
Options: 0 to 255
Serial Cmd:
<
K780,
trend analysis mode,trigger evaluation period,
number to output on
,
decodes per trigger threshold>
Default: 0
Options: 0 to 255
Serial Cmd:
<
K780,
trend analysis mode,trigger evaluation period,number to output on,
decodes per trigger threshold
>
Default: 0
Options: 0 to 65535
Serial Cmd:
<
K781,
trend analysis mode,trigger evaluation period,number to output on>
Serial Cmd:
<
K782,
trend analysis mode,trigger evaluation period,number to output on>
Serial Cmd: <K790,service unit>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K791,service unit>
Serial Cmd: <K792,service unit>