QX Hawk Industrial Imager User Manual 4-15
Setup
Height
Defines the size, in rows, of the image window. Maximum value is defined as the Maximum
row size of Image sensor, minus the row pointer value. A decrease in this value, coupled
with an increase in the row pointer value, will cause an increase in frame rate at a resolution
of 46 microseconds (row period).
Width
Defines the size, in columns, of the image window. Maximum value is defined as the Maximum
column size of Image sensor, minus the column pointer value. Changing this parameter
will have no effect on frame rate.