Chapter 5 Codes
MS-880 Industrial Long Range Scanner User’s Manual 5-29
5–Codes
Autodiscriminate
Although Autodiscriminate is not a configuration command, but it is included here
as a convenient tool for enabling most code types.
Note: If using an I 2/5 label, verify that the number of characters in the label being
scanned matches the code length enabled for the I 2/5 code type (default is 10 and 6).
See “Interleaved 2 of 5” on page 5-14.
Definition: Enables all available symbology types except PDF417, UCC/EAN 128,
and Pharma Code. The user may also individually disable/enable each
symbology type.
Usage: Commonly used for quick setup mode to detect bar code type. This is
particularly useful for users who might be unfamiliar with their applica-
tion’s symbology.
Note: It does not alter individual fields such as Start/Stop, Fixed
Length, etc. These need to be setup individually.
ESP: To enable all codes, click the Autodiscrimination button in the
Advanced Calibration menu, or type in <P> in the Terminal screen.
ESP: In the Utilities menu, right-click on Autodiscriminate and select
Enable.
Note: There will be a few seconds delay while the scanner values are
retrieved.
Serial Cmd: <P>
Default: Code 39 (only)
Options: <P> Enables all codes except noted above.
<Q> Enable Code 36 only
<R> Enable Codabar only
<S> Enable I 2/5 only