Chapter 14 Discrete I/0
MS-880 Industrial Long Range Scanner User’s Manual 14-11
14–Discrete I/0
Diagnostic Outputs
Note: See Chapter 15, “Diagnostics” for definitions and setup of Diagnostic Warnings.
Definition: Warning messages conditions relating to the MS-880 performance and
environment can be programmed to activate selected outputs (Output 1,
Output 2, or Output 3) whenever a warning condition occurs.
Usage: Useful where output warnings of scanner malfunctions can be inte-
grated to alert users and/or shut down a line.
ESP: Click the Output Format and select the Diagnostic Outputs tab to
bring up the table below:
Serial Cmd: <K713,output #,status1,status2,status3,status4,status5,status6,
status7,status8,status9>
A <K?> command returns three separate verification responses, one
for each output. A <K713?,n> command returns a verification
response for one selected output (n=1,2,3).
For example, in order to cause Output 3 to become active in response
to any warning enabled message, issue this command:
<K3,1,1,1,1,1,1,1,1,1>.
Double-click the appropri-
ate cell under Outputs and
enable/disable output in the
popup on the left.