Microscan MS-4X Manual do Utilizador Página 270

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 312
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 269
Appendix C
A-14 MS-880 Industrial Long Range Scanner User’s Manual
Appendices
IR Timeout
Embedded Menu Mode
Definition: If the infrared beam is interrupted for a period longer than the IR tim-
eout, then the scanner's IrDA port will purge any pending data, reset
its baud rate to 9600 baud, and begin transmitting a periodic query
signal.
Usage: If more than one IrDA-equipped computer terminal is to be used in
rapid sequence with the same scanner, the scanner will not communi-
cate with a second terminal until the infrared beam is blocked and the
default 40-second timeout has expired. To quickly communicate with
a second terminal, set the timeout to a smaller value.
Serial Cmd: <K103,IR status,IR timeout,menu mode>
Default: 40 seconds
Options: 0 = 3 seconds
1 = 12 seconds
2 = 20 seconds
3 = 40 seconds
Definition: Enables or disables VT100 cursor control sequences for a particular
scanner communication port. To change the status of a particular
port, issue the command through that port.
Note: The IrDA port communicates in VT100, the host, aux, and con-
figuration ports use TTY.
Usage: When a VT100-style computer terminal is connected to the host, aux,
configuration, or IrDA port, set the port mode from TTY to VT100 in
order to use the terminal's cursor control keys within the embedded
menus.
Serial Cmd: <K103,IR status,IR timeout,menu mode>
Default: VT100
Options: 0 = TTY
1 = VT100
Vista de página 269
1 2 ... 265 266 267 268 269 270 271 272 273 274 275 ... 311 312

Comentários a estes Manuais

Sem comentários