Microscan MS-4X Manual do Utilizador Página 49

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 312
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 48
Chapter 2 Communications
MS-880 Industrial Long Range Scanner User’s Manual 2-19
2–Communications
Menu Mode
Important Note: Menu Mode is only used in special cases (see “Usage” below). In
normal use the correct mode for your device is automatically selected.
Definition: In VT-100 mode, keyboard arrow keys of a VT-100 terminal (or termi-
nal emulation) may be used. TTY uses a teletype protocol.
Note: Send this command from the port to be changed.
Usage: Only useful in a special cases where a user has a TTY device (desktop
computer, laptop, etc.) and wishes to use the space bar and enter keys
to navigate through the embedded menus.
Serial Cmd: <K103,IR status,IR timeout,menu mode>
Default: The IrDA port defaults to VT-100 mode.
Options: 0 = TTY
1 = VT-100
Vista de página 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 311 312

Comentários a estes Manuais

Sem comentários