
Chapter 7 Calibration Database
MS-880 Industrial Long Range Scanner User’s Manual 7-5
7–Calibration Data-
Save Current Settings to Configuration Database
Load Current Settings from Configuration Database
Request Database Settings
Returns settings for selected Configuration Database Index. Sending <K227?,1> will
return the record for the first database index, for example:
Sending <K227?> Returns settings for the entire Configuration Database in the fol-
lowing format:
The configuration database allows the user to save multiple scanner configuration set-
tings. The database can be used simply to save most commonly used scanner config-
urations to allow scanner to be easily adaptable to changing applications, or used in
conjunction with the Optoelectric Control, to dynamically change configurations.
Definition: Saves current settings to the configuration database index.
Serial Cmd: <K227+,database index>
Options: 1 to 7
Definition: Loads a specific database index.
Serial Cmd: <K227-,database index>
Options: 1 to 7
Definition: Associates a specific tracking setting with a database index.
Serial Cmd: <K227?,database index>
Options: 1 to 7
Comentários a estes Manuais