Vista de página 175
Master Label Database
11-14 MS-880 Industrial Long Range Scanner User’s Manual
11–Matchcode
Delete Master Label Data
Definition: You can directly delete the master label data by serial command or ESP.
ESP: You can also delete master label data for any master label by erasing
the data in the Master Database popup window (under Output For-
mat) and clicking OK, as shown here.
Serial Cmd: <K231,master label number,>
To delete a master label, enter the database number and a comma,
but leave the data field empty. For example, to delete master label
#5, send the following <K231,5,>. The command is entered with a
blank master label data field which tells the scanner to delete the
selected master label from the database.
Default: (no data)
Options: Any combination of ASCII text up to the maximum indicated in
“Maximum Characters for Master Label Database” on page 11-13.