
Autocalibration by Embedded Menu
6-12 MS-880 Industrial Long Range Scanner User’s Manual
6–Autocalibration
Advanced Autocalibration Setup Embedded Menu
The Advanced Autocalibration Setup menu allows you to change the starting focus
position and the number of focus steps during the first pass.
For example, if you are preparing to do autocalibration on labels whose minimum dis-
tances from the scanner is 40 inches, there is no reason for autocalibration to cycle
through all of the focal positions inside 40 inches. Figure 6-7 includes a table that
associates several starting focus positions with minimum label distances from the
scanner. Use this table to estimate your starting focus position.
To increase Starting Focus Position, type T. To decrease it, type R.
To increase the First Pass Focus Step, type G. To decrease it, type F.
Increasing First Pass Focus Step will speed up the autofocus process, but can also
cause autofocus to skip over a bar code symbol and not decode it.
Note: All single letter commands must be entered in upper case.
Auto Range is disabled by default. To enable, press A. See page 6-6 for an explana-
tion of auto range.
Figure 6-7 Advanced Autocalibration Menu
Comentários a estes Manuais