Microscan MS-4X Manual do Utilizador Página 82

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 312
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 81
Multilabel
4-16 MS-880 Industrial Long Range Scanner User’s Manual
4–Read Cycle/Trig-
Multilabel
Number of Labels
Definition: Multilabel allows the user to define up to 12 bar code labels that can
be read in a single read cycle.
Usage: Multilabel is commonly used in shipping applications where a shipping
label contains individual bar codes for part number, quantity, etc. This
feature allows one trigger to pick up all the labels. AIAG and UCC/EAN-
128 are two application standards that address this need.
Conditions: The following conditions apply:
1. Each bar code label must be different to be read.
2. The maximum number of characters in a read cycle is 32,520 for all
labels.
3. The maximum number of characters the scanner can transmit is
calculated by: Preamble + maximum number of labels
*
(aux id +
symbology id + maximum label length + quality output + ((number
of insertion cells x cell length)+ separator) + postamble + LRC =
37,425.
4. All noread messages are posted at the end of the data string.
5. If more than one label is within the scan beam at the same time,
label data may not be displayed in the order of appearance.
6. If Matchcode Type is set to Sequential or if Trigger is set to
Continuous Read 1 Output, Number of Labels will default to 1
(if set to any number greater than 1).
Definition: Number of Labels is the number of different labels that can be read in
a single read cycle.
Serial Cmd: <K222,number of labels,multilabel separator>
Default: 1
Options: 1 to 12
Vista de página 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 311 312

Comentários a estes Manuais

Sem comentários