11-2 MS-880 Industrial Long Range Scanner User’s Manual
11–Matchcode
Matchcode by ESP
Matchcode by Serial Command
Command Title
old
cmds
new
cmds
Format
Matchcode Type Kn K223,
<K223,type,sequential matching,match start
position,match length,wild card character,
sequence on noread,sequence on mismatch>
Master Label Database Size KM K224, <K224,number of master labels>
New Master Pin Kz K225, <K225,status>
Sequential Step K228, <K228,sequence step>
Enter/Delete Master Label
Data
M K231,
<K231,master label number,master label data
[no data will delete]>
Request Master Label Data M K231,
<K231,?>[for all] or
<K231,master label number?>
Operations Status Request KV? K399? <K399?>