Laser Setup
9-6 MS-880 Industrial Long Range Scanner User’s Manual
9–Raster/Laser Con-9–Raster/Laser Con-
Laser Setup
The laser can be turned off between read cycles and the duration of the scan and
hence the width of the scan can also be adjusted.
Laser On/Off Status
Note: A serial or external trigger must be enabled for Laser On/Off to take effect.
Note: Laser On/Off is not recommended when New Trigger is enabled, since the
laser will effectively remain on continuously.
Definition: When enabled, the laser is ON only during the read cycle. When dis-
abled, the laser operates continuously.
Usage: Laser On/Off extends the life of the laser. It is useful where there
are significant time gaps between symbols. It also provides visual
confirmation of a read cycle duration and minimizes laser exposure to
people.
Serial Cmd: <K700,laser on/off status,laser framing status,laser off time,laser on
time,laser power>
Default: Disabled
Options: 0 = Disabled
1 = Enabled