Chapter 14 Discrete I/0
MS-880 Industrial Long Range Scanner User’s Manual 14-9
14–Discrete I/0
Trigger Evaluation Period
Number Before Output
Reads per Trigger Threshold
Definition: The number of trigger events to examine within the trend analysis
event.
Serial Cmd: <K720,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trig-
ger threshold>
Default: 0
Options: 0 to 255
Definition: Sets the number of events (matches, mismatches, or noreads as con-
figured by Output On) that must occur before activating the associated
output.
Serial Cmd: <K720,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trig-
ger threshold>
Default: 0
Options: 0 to 255
Definition: When Reads/Trigger trend analysis mode is enabled, the Reads per
Trigger Threshold value is the minimum number of successful reads
required during a read cycle.
Helpful
Hints:
You can determine the expected number of scans during a read cycle
by multiplying the enabled Number of Scans per second times the
number of seconds in the read cycle. You can also use Quality Output
(see “Quality Output”) to observe the number of successful reads.
Serial Cmd: <K720,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trigger
threshold>
Default: 0
Options: 0 to 65,535