Scan Speed
(factory setting)
Definition: Allows the user to set the number of scans per second by controlling
the spinning mirror motor speed.
Usage: Typically, to ensure a minimum number of scans, faster scan speeds are
used for fast moving labels and/or longer labels with larger bar widths.
Note: Scan beams will be moving faster across labels further out in the
scan range since the moving beam is being projected from a spinning
mirror.
Serial Cmd: <KE500,scan speed>
Default: 400
Options: 400 to 1000