Microscan MS-4X Manual do Utilizador Página 223

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 312
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 222
Chapter 15 Diagnostics
MS-880 Industrial Long Range Scanner User’s Manual 15-5
15–Diagnostics
Laser High Warning
Transmits a message whenever the laser current exceeds a factory-calibrated refer-
ence value which cannot be altered. The message repeats once every 30 minutes until
the condition is corrected.
Laser High Status
Laser High Message
Definition: Enables the Laser High message.
Usage: Alerts the user to impending laser failure. (Contact Microscan Service.)
Serial Cmd: <K400,warning message status,laser high status,laser low status,
novram/reset warning status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Defines the Laser High message.
Serial Cmd: <K404,laser high message>
Default: HIGH-LASER
Options: Any 1 to 10 character ASCII string except NUL, <, or >.
Vista de página 222
1 2 ... 218 219 220 221 222 223 224 225 226 227 228 ... 311 312

Comentários a estes Manuais

Sem comentários