Microscan MS-4X Manual do Utilizador Página 180

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 312
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 179
12-2 MS-880 Industrial Long Range Scanner User’s Manual
12–Outputs
Outputs by Serial Command
Outputs by Embedded Menu
For information on accessing the embedded menus, see “Embedded Menus” on page
A-23.
From the Main menu, scroll down through the options and select the following screen:
Command Title
old
cmds
new
cmds
Format
Serial Verification KS K701,
<K701,serial command echo status,serial command
beep status,control/hex output>
Beeper Ku K702, <K702,status>
Quality Output KJ K704, <K704,quality output separator,reads/trigger status>
Bar Code Output Kl K705, <K705,status,when to output>
Output During Diagnostic
Warning Messages
K713,
<K713,channel,status1,status2,status3,status4,
status5,status6,status7,status8,status9>
Noread Message Kk K714, <K714,status,message>
Vista de página 179